MEE3 Series
1kVDC Isolated 3W Single Output DC/DC Converters
TEMPERATURE DERATING GRAPH
OUTPUT VOLTAGE TOLERANCE ENVELOPE
5%
4.5
l oa
3.0
85°C
V NOM
Typic
a
L
d Lin
e
2%
0%
1.5
Safe Operating Area
-4%
10
25
50
75
100
0
-40
0
50
100
150
Output Load Current (%)
Ambient Temperature (°C)
The voltage tolerance envelope shows typical load regulation characteristics for
this product series. The tolerance envelope is the maximum output voltage varia-
tion due to changes in output loading.
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a speci?ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MEE3 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MEE3 series has been recognized by Underwriters Laboratory for functional isolation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation sys-
tem. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MEE3 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from speci?ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of
260°C for 10 seconds. The pin termination ?nish on the SIP package type is Tin Plate, Hot Dipped
over Matte Tin with Nickel Preplate. They are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
SAFETY APPROVAL
The MEE3 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional isolation in a maximum still air ambient temperature of 63°C and/or case tempera-
ture limit of 91°C. Case temperature measured on the face opposite the pins. File number E151252 applies.
The MEE3 series of converters are not internally fused so to meet the requirement of UL 60950, an input line fuse should always be used. An anti-surge 2.5A should be used for
MEE3S05xxSC models, and an anti-surge 1A should be used for MEE3S12xxSC models. All fuses should be UL approved and rated to at least the maximum allowable DC input
voltage.
www.murata-ps.com/support
KDC_MEE3.A03 Page 2 of 5
相关PDF资料
MER1S1515SC CONV DC/DC 1KVDC TH 1W 15-15V
MEV1D2412DC DC/DC 3KVDC DIP 1W 24V TO +/-12V
MEV3S0509SC CONV DC/DC 3W 5V IN 9V OUT SIP
MEXY2A562K CAP FILM 5600PF 275VAC RADIAL
MH3225-900Y BEAD FERRITE 90 OHM 2A 3225
MHV13C226MAT2A CAP CER 22UF 25V 20% X7R SMD
MK03V71R5BAT2A CAP CER 1.5PF 250V NP0 0603
MKP1847620354Y5 CAP FILM 20UF 350VAC RADIAL
相关代理商/技术参数
MEE3S0515SC 功能描述:DC/DC转换器 3W 5Vin 15Vout 200mA Iso SIP RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
MEE3S1205SC 功能描述:DC/DC转换器 3W 12Vin 5Vout 600mA Iso SIP RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
MEE3S1209SC 功能描述:DC/DC转换器 3W 12Vin 9Vout 333mA Iso SIP RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
MEE3S1212SC 功能描述:DC/DC转换器 3W 12Vin 12Vout 250mA Iso SIP RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
MEE3S1215SC 功能描述:DC/DC转换器 3W 12Vin 15Vout 200mA Iso SIP RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
MEE40431401 制造商:LG Corporation 功能描述:Heater,Sheath
MEE40431601 制造商:LG Corporation 功能描述:Heater,Sheath
MEE41599204 制造商:LG Corporation 功能描述:Heater,Sheath